SPECIFICATIONS |
|
|
DATA PROCESSING UNIT
|
| Display |
240¡¿64 dot matrix LCD. 30 column¡¿8 row alpha numeric
display. Graphics for full multichannel analyzer capability of 2,000
data storage channels. High contrast, wide viewing angle. |
| Controls |
Sealed keypad. 21 keys including ON, OFF, CONT/PAUSE,
) through 9, decimal point, backspace and six "soft" keys. Measurements
controlled either through keypad or push button on probe. |
| Tone Generator |
Acknowledges keyboard strokes. Distinctive tone on source
opening. Volume control. |
| Serial Output |
RS 232 serial port for output to printer or computer.
Configurable by menu. |
| Dimensions |
13 in ¡¿ 12 in ¡¿ 4 in (32 cm ¡¿30 cm ¡¿ 10 cm) |
| Battery |
Seven special high capacity NiCad cells in quick change
pack. 6 to 8 hours of continuous use. Battery pack can be interchanged
with the spare (separately charged) pack without loss of stored data. |
| Charger |
For AC operation of processing unit or recharging internal
battery. 110/220 VAC, 50¡ 60 Hz. Must be used with charger adapter
for spare battery recharge. Recharge time, approximately 14 hours. |
|
 |
|
PROBE
|
| X-Ray Excitation Sources |
45 mCi Fe-55 and 5 mCi Cd-109 |
| X-Ray Detector |
High resolution HgI2 |
| Source Position Indication |
Flashing red light indicates source-on condition. Color
coded position indication dots can be seen through side window. |
| Push Button |
Starts, halts and resumes measurement. |
| Measurement Aperture |
0.75 in ¡¿ 0.55 in (19mm¡¿14mm) |
| Dimensions and Weight |
6.8 in ¡¿ 4.3 in ¡¿ 2.0 in (17cm¡¿11cm¡¿5cm) 2.4 lb (1.1kg) |
| Aperture Window |
0.001 in (25 micron) polypropylene. User-replaceable |
| Cable to Data Processing Unit |
6 ft. (2m) |
| Battery |
3.6 volt lithium detector bias battery. One year nominal
life. User-replaceable, TN supplied part. |
|
| |
|
SYSTEM
|
| Main Carrying Case |
Holds basic unit consisting of: probe, data processing
unit, battery charger, shoulder strap. Fe/Al calibration sample and
probe safety cover with Ti calibration sample. Size: 19.5 in ¡¿ 28.5
in ¡¿ 9.5 in (50cm¡¿72cm¡¿24cm) Weight: 34.5 lb (15.6kg) loaded. |
| Accessory Case |
Holds spare battery pack for data processing unit, spare
charger, charger adapter, probe stand, small sample supporting fixtures,
screw driver (for battery pack change-out), spare windows and instruction
manual. Size: 16 in ¡¿ 14.7 in ¡¿ 7 in (41cm¡¿37cm¡¿18cm) Weight: 20 lb
(9.1 kg) loaded |
| Operating Temperature |
32¢µ to 120¢µ (0¡É to 49¡É) |
| Storage temperature |
-4¢µ to 105¢µ (-20¡É to 40¡É) |
|
| |
 |
APPLICATION |
|
|
|
 |