Four Channel Controller |
|
Power: field selectable
for AC (115 and 230 VAC) or DC (24 VDC) |
|
AC Input |
115 VAC 50-60 Hz standard; 230 VAC
50-60 Hz |
|
DC Input: |
12 V-24 VDC Minimum 3 amp input |
|
Battery Back-up:
|
12VDC supply; 50
hours in normal operation with 4 H2S sensors.
|
|
Fuse: |
Auto reset fuse 250 mA @ 30 watts |
|
Environmental: |
|
Humidity: |
5 to 99% RH non-condensing |
|
Operating Temperature: |
VDC: -40 to +122°F (-40 to +50°C)
VAC and Battery Back-up: -4 to +122°F
(-20 to +50°C)
|
|
Enclosure
Rating: |
Nema 4X |
|
Physical: |
|
Size: |
3.75 x 15.75 x 9.5 in. (9.5 x 40 x 24.1 cm) |
|
Weight: |
17.8 lb (8.1 kg) |
|
Enclosure: |
16 gauge stainless steel w/carry
handles |
|
Wire Terminals: |
Screw type terminal blocks |
|
Wiring Ports: |
Six (6) each 3/4 in. (22 mm) NPT
ports |
|
Mounting: |
Predrilled mounting flanges,
hinged door |
|
Alarms: Four gas setpoints
- user programmable |
|
Audible: |
85 dB (activation field
selectable) |
|
Outputs: SPDT relays;
10 amp @ 110 VAC/24 VDC, 8 amp @ 230 VAC |
|
Gas Alarms:
|
Three (3): Low, high and high/high
common. de-energized gas relays are field selectable for latching or
non-latching
|
|
Fault Alarm:
|
One (1) normally energized and
non-latching common relay
|
|
Display: |
|
LCDs: |
Four (4) independent alphanumeric Status
displays
Field selectable readouts: %LEL,
ppm and/or other
|
|
Backlight: |
In VAC operation |
|
LED Indicators: |
Gas Alarms (3) red: LOW; HIGH;
HIGH/HIGH
FAULT aLARM (amber)
Power ON (2): AC icon (green); DC
icon (green)
Gas concentration icons (3): ppm,
% LEL and % O2
|
|
Multi-Function External Controls: |
|
Pushbuttons switch |
Alarm Reset/Acknowledge; Audible
mute; Display Peak (Max) Exposures and Up/Down Setpoints |
|
Security Key lock switch |
(Three position) ON/OFF; lamp Test;
Calibration and alarm setpoints |
|
RRJ Transmitter c/w Sensor
(Accessory) |
|
Output Signal |
4-20 mA |
|
Supply voltage |
24 V (powered by controller |
|
LED Indicator |
Advises: Sensor Fault, Sensor Expiry
Warning, End of Sensor Life |
|
Sensor Types |
Hydrogen Sulfide (0-100 ppm):
Electrochemical Combustibles 0-100% LEL: Electrocatalytic |
|
Operating Temperature |
-40 to +122°F (-40 to +50°C)
|
|
Signal Distance |
1,000 feet (305m) |
|
Physical |
Polyurethane encapsulated sensor head |
|
Size |
2.65 x 2.3 x 3.25 in. ( 6.73 x 5.84 x
8.25 cm) |
|
Weight: |
approx 6.2 oz. (175 gms) |
|
Connector |
Accepts Field wiring accessory kit
or |
|
Dual Alarm Bar (Optional) |
|
Audible |
101 dB siren activates on High,
High/High and Fault alarm. Field selectable for each channel |
|
Visual: |
60,000 candlepower strobe (all alarm
conditions0 field selectable for each channel |
|
Physical |
Stainless steel enclosure with variable
mounting predrilled flanges. Mounts remotely or directly on the
Controller |
|
Size |
4.5 x 8.3 x 6.5 in (11.4 x 21.1 x 16.5
cm) |
|
Weight |
4.0 lb. (1.8 kg) |
|
Cable: |
Standard 5.5 ft 91.5m), longer lengths
available |
|
Warranty: |
All system components 2 years
including sensors
Expected Life: H2S 3 years zero maintenance
Combustible 3 years |