Technical Specifications & Options for the 4100TC Typical Measured Accuracy:
Better than 0.5% of reading, depending on application and averaging time. Typical Control Accuracy: ± 0.002 mils. Measuring Range: 10 mils to 2 inches (0.25 to 50 mm @ specific gravity = 1).
Averaging Time: Operator selectable, 50 ms to 99 seconds. Response Time: 50 ms. Operating Temperatures: Sensor: To 130°F (55°C) without watercooling. Console: To 130°F (55°C). Principle of Operation:
Gamma Backscatter with scintillation crystal, photomultiplier detector. Source Characteristics: Am241 with an activity of 150 mCi (5.55 Gbq), energy of 60 Kev, and halflife of 455 years.
Measured Area: Approximately 0.25" (6 mm) in diameter. Options SPC/SQC: Analysis and report package with x, range, Cpk and Ppk
Remote CRT Displays: Consult factory for available sizes Analog Outputs:
Programmable isolated outputs: absolute or centered on target. Communications: Bi-directional communications packages for host computer or PC. Optional drivers for popular SCADA programs. Data Historian:
Archive data on a PC running DOS or Windows. Analyze data on popular spreadsheets and databases. Electronics Console Power:
90/240 VAC 50/60 Hz, 2.5A Size: HWD: 9 x 19 x 18 in. (225 x 480 x 450 mm) Weight: 30 lbs. (13 kg) Ambient Temperature: To 130°F (55°C) CE Mark:
Conforms with EC directives on electromagnetic compatibility and safety.
CRT Power: 90/240 VAC 50/60 Hz, 2.5A Size:
HWD: 12.25 x 19 x 18.5 inches (3 10 x 480 x 470 mm) Weight: 33 lbs. (15kg) Ambient Temperature: To 130°F (55°C)
Rotator Power: 90/240 VAC 50/60 Hz, 2.5A Size: HWD: 63 x 30 x 28 inches (3 10 x 762 x 1609 mm)
Weight: Approximately 375 lbs. (170kg) Pipe Diameter: 4100-10T: 0.625" to 10" (16 to 250 mm) 4100-20T: 8" to 20" (200 to 500 mm)
4100-30T: 18" to 30" (450 to 760 mm) Sensor Mount Device: Covered by US Patent No. 5,311,785 May 17,1994. |