Beta Transmission Technical Specs NDC Infrared Engineering logo

Technical Specifications for the Beta Transmission Sensor

 

MODEL

303

302

301

Isotope

Promethium-147

Krypton-85

Strontium-90

Activity

500mCi (18.5GBq)

200mCi (7.4GBq)

10mCi (0.37GBq)

Energy (Emax)

0.225Mev

0.687Mev

2.283Mev

Half-Life

2.62 Years

10.7 Years

29 Years

Measurement Range (SG = 1)
(Extended Ranges available upon request)

0-0.008 in
(0-200g/m²)

0.001-0.047 in
(25-1200g/m²)

0.004-0.215 in
(100-5500g/m²)

Repeatability (2s, 1s)*

±0.1% or 0.05g/m²
(the greater)

±0.2% or 0.2g/m²
(the greater)

±0.3% or 1.5g/m²
(the greater)

Air Gap

0.4 in (10mm)

0.63 in (16mm)

1.3 in (33mm)

*The repeatability specifications reflect the weighted mean of all possible sources of dynamic error, including the maximum allowable sensor X, Y and Z-Axis misalignment, possline / flutter variation, temperature change, etc, Measurement tests to confirm the above are encouraged.

Measurement Footprint

    Models 303 & 302: 0.3 x 2 in (8 x 50mm)
    Model 301: 1.2 in (30mm) dia

Streak Resolution: 1/32 in (1mm) streak resolution at a scanning speed of 5 in/s (7.7m/min)
Passline Tolerance: ±0.125 in (±3mm)
Time Constant: Analog = 5ms  (Typical digital accumulation time 15ms)
Operating Temperature: 32-140°F (0-60°C)
Shutter: Electric Solenoid Driven, Fail-Safe
Dust Covers: Easily removed for replacement, repair or cleaning.
Air Gap Temperature Compensation: Standard on Model 303 and 302, incorporating high speed temperature sensors in each of the critical air columns for fast temperature changes and gradients.
Construction: 0.200 in (5mm) Cast aluminum housing with Stainless Steel Allen Head fasteners; Exposed surfaces are polyester powder coated. Sealed Quick Connect Electrical Connector; IP64 (DIN 40050) Rating; Available for hazardous environments (Class I, Division I, Group D)
Scanner:
O-Frame Scanner

Korins Co.,Ltd.
Rm301, #24-2, Youido-Dong, Youngdungpo-Ku, Seoul, Korea
Tel. : (02)780-4848 Fax.:(02)780-1244, 786-1244

sales@korins.com