Infragauge 55 Blown Film Sensor Technical Specs NDC Infrared Engineering logo

Technical Specifications of the Infragauge 55 Blown Film Sensor

Measurement scope: Blown films based on PE, PP and PCV
Output modes: Absolute, deviation from target, and percentage deviation. Selectable for each channel.
Power supplies: 100-120V/200-240V (-15%+10%) 50-60Hz
Display: 4 digit 7 segment bright green LED
Accuracy: +/- 0.25 microns (Application dependent)
Air gap: +/- 25 mm each side of film (see diagram)
Sampling area: Nominal 10 mm diameter
Stability: +/- 0.1microns
Ambient light sensitivity: Less than 0.25 micron change with fluorescent or incandescent (40W at 1m)
Response time: 0.2 second (linear) 0.5 to 1000 seconds (exponential)
Cable: Head to ECU 5 m (standard) to 100 m max.
Serial outputs: RS232C/422/485 selectable serial interface. Optional Databus interface.
Alarms: High and low on each channel. Separate settings for each mode. Isolated relay contact closure 50 mA 50 V max.

Mounting and Mechanical

Environmental: Sensors to IP65 (NEMA 4 equivalent
                            ECU to IP54 (NEMA 4 equivalent) (panel mount)
                            ECU to IP54 (NEMA 2 equivalent) (free standing)
                            ECU to IP55 (NEMA 4 equivalent) mounted in 19 inch rack dustproof cabinet option with paperless recorder
                            showing sensor output and die bolt events.
Ambient temperature: 0-50 degrees Celsius, sensor and ECU
CE compliance: Low Voltage Directive EN 61010-1
                            EMC Directives EN50081-1 & EN 50082-2
Weights: Sensor 4kg, ECU 4kg
Dimensions:
See IG55-BF diagrams

Korins Co.,Ltd.
Rm301, #24-2, Youido-Dong, Youngdungpo-Ku, Seoul, Korea
Tel. : (02)780-4848 Fax.:(02)780-1244, 786-1244

sales@korins.com