Technical Specifications for the Infragauge 55 Transmission Sensor Plastic film thickness:
Monolayers: 10 - 400 microns (accuracy ± 0.25 microns*)
400 microns - 2 mm (accuracy ± 1 micron*)
Barrier layers (EVOH, Nylons, etc.) (accuracy ± 0.3 microns*)
Nonwovens: Moisture content: 0 - 15 % (accuracy ± 0.1%*) Impregnations: Resin weight: 20 - 300 gsm (accuracy ± 1.0 gsm*) Paper & Board:
Moisture over basis weight range 50 - 400 gsm* (accuracy ± 0.1% moisture*) Measurement scope: One sensor - two components simultaneously
Two sensors - one component each sensor
Output channels: One output for each component or one output for one component and one output for the difference of the two components Output modes:
Absolute, deviation from target, and percentage deviation. Selectable for each channel. Measurement wavelengths: Up to 5 per sensor with Dual Detector Referencing Calibration stations: 80 per channel
Power supplies: 100-120V/200-240V (-15%+10%) 50 - 60 Hz Power consumption: One sensor 35VA, two sensors 70 VA max Display: 4 digit 7 segment bright green LED Airgap: See diagrams below
Sampling area: 10 mm circular Web flutter tolerance: ± 5 mm Relative head movement: X/Y/Z ± 3 mm Ambient light sensitivity: Mercury (250W @ 2m) < 0.1% absorption
Sodium (250W @ 2m) < 0.1% absorption
Fluorescent (40W @ 1 m) < 0.1% absorption
Incandescent (40W @ 1 m) < 0.1% absorption
Response time: 0.2 second (linear) 0.5 to 1000 seconds (exponential) Cable: Sensor to ECU 5m (standard) optional to 100m max. Analog outputs: Deviation mode ± 10 V (10mA max)
Absolute mode 0 - 10 V (10mA max)
4 - 20 mA or 0 - 20 mA Serial outputs:
RS232C/422/485 selectable serial interface. Formatted output to printer. Dumb terminal mode. Full two-way communication to host computer including diagnostics Databus options: Profibus, DeviceNet, Modbus, DDE Server
Alarms: High and low on each channel. Separate settings for each mode. Isolated relay contact closure 50mA 50V max Mounting and Mechanical Environmental:
Sensors to IP65 (NEMA 4 equivalent)
Air purged window, optional
ECU to IP65 (NEMA 4 equivalent) (panel mount)
ECU to IP54 (NEMA 4 equivalent) (free standing)
ECU to IP55 (NEMA 4 equivalent) (mounted in 19" rack cabinet option)
Ambient temperature: 0-50 degrees Celsius Electrical safety: Air purge protection. Eurostandard EN50016 system, optional CE Compliance:
Low Voltage Directive EN 61010-1, EMC Directives EN50081-1 & EN 50082-2 Weights: Sensor 12 kg, ECU 4 kg Dimensions: See IG55-TS diagrams * dependent upon application |
|
|
|