Features |
|
|||||||||||||||||||
| The Silent Partner Plus is a precision 3 channel true RMS recorder. Small and compact, the Silent Partner Plus uses a 12 bit Analog to Digital converter for accurate readings. Recording parameters are set using easy to use Silent Partner software. | ||||||||||||||||||||
![]() Silent Partner Plus Screen Capture: |
||||||||||||||||||||
|
|
||||||||||||||||||||
|
|
|||||||||||||||||||
Silent Partner Plus Specifications |
||
|---|---|---|
|
|
|
|
| Maximum Channels | Three | Selectable storage for 1, 2, or 3 channel operation. |
| Range | 0 - 1 VAC input. Actual current range depends on CT used. | True RMS for 50/60 Hz. operation. |
| External Connections | Aux. power, download, 3 x CT connectors. | |
| Sensor Type | External CT's. | |
| Sampling Rate | 2 to 4 seconds. | Set via Silent Partner software. |
| Storage Rate | 32 seconds to 15 minutes. | Set via Silent Partner software. |
| Parameters Stored | Avg, min/max, or min/max/avg. | Set via Silent Partner software. |
| Samples per Average |
16 at 32 second storage. 256 at 15 minute storage. |
Depends on storage rate. |
| Memory | 64K RAM. | |
| Memory Treatment | Stop when full or wrap. | Set via Silent Partner software. |
| Storage Capacity |
43,632 readings for 1 channel, avg. only. 14,544 readings for 1 channel, min/max/avg. |
Storage available depends on number of channels, storage mode, and memory size. |
| Indicators | Flashing LED when logging. | |
| Power | Internal battery and/or adapter. | Uses standard 9V alkaline. |
| Battery Life | At least 7 days (unit can operate from external adapter as well). | |
| Communications | RS232, support for remote setup. | |
| Software | Silent Partner for Windows. | Requires PC running Windows 3.1 or greater and 1 free serial port. |
| Accuracy | ?0.25 % Range + CT error | |
| Dimensions | 6?quot; x 3' x 1" (172 mm. x 76 mm. x 25 mm.) | |
| Weight | 6 oz. (162 grams) | |
| Safety | Isolation of measurement circuit via optional CT's or PT's | |
| Operating Temperature | - 40ºC to 60ºC | |