TFIA Series High Volume Air Samplers
- Indoor or outdoor sampling
of airborne particulates
- 0-70 cubic feet per minute
(cfm) [0-2 cubic meters per minute (cmm)] flow range
- Spot or continuous
monitoring
- Portable and lightweight
- Built-in rotometer for
instantaneous flow reading
- Includes 4" (10.16
cm) diameter filter holder assembly
- For use in normal,
non-explosive atmospheres
- Complete accessories
available for use with Total Suspended Particulate (TSP)
and PM10 Systems for U.S. EPA compliance
- Made in U.S.A.
Standard Models:
TFIA 110-125
Volts AC/DC, 50-60 Hz Best seller!
TFIA-F
Includes built-in
Flow Adjuster - 110-125 Volts AC/DC, 50-60 Hz
TFIA-DTM4CDT
Includes built-in
Count Down Timer - 110-125 Volts AC/DC, 50-60 Hz
TFIA-2
220-240 Volts
AC/DC, 50-60 Hz Best seller!
TFIA-2F
Includes built-in
Flow Adjuster - 220-240 Volts AC/DC, 50-60 Hz
TFIA-2DTM4CDT
Includes built-in
Count Down Timer - 220-240 Volts AC/DC, 50-60 Hz
TFIA-4
24 Volts DC (35 cfm [1 cmm] maximum flowrate) 16 Amps
TFIA-4BC
24 Volts DC with battery cable with clamps, 16 Amps
When normal currents are
not available 24 Volts DC models are ideal for remote field
use with 2 of 12 Volt DC automobile batteries
in series.
Other
special models available.
Dimensions: 8-1/2
" x 7-1/2 " x 7-1/2 (21.6 x 19.1 x 19.1 cm)
Carrying weight:
10 lbs. (4.5 kg)
Construction:
Sturdy Lightweight Dural Main Housing
Description
Portable Air Sampler for
indoor and outdoor sampling for all types of airborne
particulates including environmental pollutants, nuclear and
biohazards, industrial, governmental and military tests and
studies, mine air hazards, factory dusts, chemical,
radiological and toxicological analyses, as well as
innumerable other types of research, quality control and
testing applications.
Principle of Operation
Large volumes of air are
drawn through a filter by a high-speed rotary motor.
Particulate matter in the air collects on various types and
sizes of filter papers including Glass Fiber Filter Media.
Standard Features
Universal motor, Pump,
Variable Orifice Flowmeter calibrated 0-70 CFM or 0-2 CMM;
4" (10.16 cm) diameter Filter Holder Assembly, Filter
Support Rod and Stainless Steel Mesh Adapter, carrying
handle, on/off current toggle switch, 8 foot (38 cm)
grounded cordset.
Analysis of Collected
Samples
Filters can be analyzed
gravimetrically, by weighing, taring, ashing, spectrography,
atomic absorption, comparator, microscopic count,
chromatography, atomic colorimetric assay, and gammaray
spectroscopy, x-ray fluorscopy and neutron activation
etc., to identify pollutants and measure their
concentrations.
Operation
Proper filter is inserted
into appropriate filter holder of air sampler and sampler is
then ready for test operations. Initial flowrate and
sampling time are recorded. Flowrate is governed by size and
type of filter used.
The Staplex SH4 4"
Diameter Filter Holder Assembly, is equipped with filter
support rod to be used as back support for Staplex TFA2133
filters. In addition. when using Staplex TFA41 Filter Paper
and Staplex TFAGF41 Glass Fiber Filters, a special 4 "
Diameter Stainless Steel Screen is required (included).
Calibration:
The rate of flow is
measured by means of an indirect, variable orifice flow
meter (pressure indicator gauge). This indicates the
pressure drop across an orifice in the housing and is
calibrated against a standard orifice on the intake.
Flowrate is determined by saturation of filter paper and
should be recorded accordingly during sampling test periods.
User can calibrate the flow meter in the field using the US
EPA prescribed method for calibrating High Volume Air
Samplers, using Staplex Model CKHV and CKHV810 Calibration
Kits. (See
additional data sheet).
General:
Can be used indoors or
outdoors. for mobile or fixed position operation either
horizontally or vertically. Also available is a convenient
Staplex TR-1 Tripod mounting. When required for protracted
periods outdoors a special outdoor enclosed shelter in
Aluminum (SAM) or Wooden (SWM) is available.
Maintenance:
TFIA series models can be
operated continuously when using TFA810 and TFAGF810 8"
x10" filters continuously, with filters checked and
changed as need, based on particulate saturation. No
lubrication of any motor parts is required. Motor brushes
should be check after every 600 hours of usage and changed
as needed. Changing of brushes is recommended for every 800
- 1,000 hours of usage.
Accessories
(see
additional data sheet)
TFA41 Filter Paper 4"
dia. (100/box)
TFAGF41 Glass Fiber Filters
4" dia. (100/box)
TFA810 Filter Paper
8"x10" (100/box)
TFAGF810 Glass Fiber Filters
8"x10" (100/box)
TFA69 Filter Paper
6"x9" (100/box)
TFAGF69 Glass Fiber Filters
6"x9" (100/box)
TFA2133 Filters, 4"
diameter (100/box)
Filter Holder
Assemblies - SH810
8" x 10" and - SH69 6" x 9"
Filter Holder Assemblies, as well as additional SH4, 4"
Diameter Filter Holder Assemblies are available. The
larger SH69 and SH810 Filter Holder Assemblies are made of
polished Stainless Steel with Dural adapter ring and filter
frame. SH25 Filter Holder Assembly uses cartridge
filters and is recommended for short term radioactive iodine
grab sampling
All Filter Holders are
interchangeable, which is an essential feature when tests
require the use of several samples of the same or different
type filters during critical tests in which the operator can
use several loaded filter holders in order to avoid
contamination
Flow
Adjuster/Brush Seater - Models FA-1 and FA-2
- To reduce flow rate from full flow rate to
desired flow rate or to "seat" new motor brushes. (see
additional data sheet)
Calibration
Kits - Models CKHV and
CKHV810 - U.S. EPA prescribed method
for accurate calibration of High Volume Air Samplers. U.S.
EPA recommends that High Volume Air Samplers be re-calibrated
at least once per year (or when major components such as the
motor or flowmeter are changed). Model CKHV used with 4"
diameter filter holder assembly. Model CKHV810 used with
4" or 8" x 10" filter holder assemblies. (See
additional data sheet)
Tripod
Mounting - Model TR-1
Where normal flat surfaces are not available for
conducting air sampling tests. The Staplex® TR-1 Tripod
is recommended for mounting the TFIA series High Volume Air
Sampler. The Air Sampler and Tripod can be assembled and
placed in any required location in a matter of minutes.
Maximum extended height: 60"
(152 cm) / Collapsed height: 22.5" (57 cm)
Aluminum
Outdoor Shelter - Model SAM
U.S.
EPA prescribed design for enclosed Outdoor Shelter for
continuous sampling with maximum air flow. Protects filter
from rain and other weather elements. Designed for use with
TSP (Total Suspended Particulate) Systems. [requires SH810
filter holder assembly]
Timers
DTM-1 and DTM-2
Digital 7-Day Timer
Turns Air Sampler "ON" and "OFF" at
set times, 24 hours a day, 7 days a week. All functions are
digital and quartz crystal controlled; includes digital clock
with 1/4-in. LED display and 7.2 VDC rechargeable stand-by
battery; intuitive programming format. Specify Model DTM-1 for
120 VAC, 60 Hz; Model DTM-2 for 230 VAC (specify 50 or 60 Hz
when ordering).
MT-1
and MT-2 Mechanical 7 Day Timer Turns Air
Sampler "ON" and "OFF" at set times ±15
minutes, 24 hours a day, 7 days a week. Specify Model MLT-1
for 120 VAC, 60 Hz; Model MLT-2 for 230 VAC, 50 Hz
DTM-4CDT
Digital Countdown Timer
Turns Air Sampler "OFF" after preset times.
Features LCD display and thumb-wheel setting dials. (range
from 99,999 hours to 1 second). Size: 3" x 4-1/4" x
5" (7.6 cm x 10.8 cm x 12.7 cm); Weight: 1.75 lbs. (0.8
kg). Usable for 110-125 VAC, 220-240 VAC and 24 VDC.
ETI-1
and ETI-2 Elapsed Time Indicator Shows
sampler run time in hours and hundreths (99,999.99 hours).
Standard models are non-resettable mechanical models. Specify
Model ETI-1 for 120 VAC, 60 Hz.; Model ETI-2 for 220 VAC, 50
Hz. (Re-settable model ETI-1R is also available for 120 VAC.)
Constant
Flow Controllers Models FC-1 and FC-2 - Automatically
maintains a constant mass flow through an High Volume Air
Sampler regardless of filter loading, atmospheric conditions
and line voltage. Specify Model FC-1 for 115 VAC; Model FC-2
for 230 VAC. [requires SH810 filter holder assembly]
Models
FC-1ETM and FC-2ETM include built-in non-resettable
Elapsed Time Indicator.
Models
FC-1MLT and FC-2MLT include built-in Mechanical 7-Day
Timer and non-resettable Elapsed Time Indicator.
Flow
Recorder - Models FR-1 and FR-2 - Provides a
permanent record of High Volume Air Sampler performance during
a 24-hour period. Specify Model FR-1 for 115 VAC; Model FR-2
for 230 VAC.
Annular
Kinetic Impactor - Model AKI - designed
for inertial collection especially of radioactive particles.
Carrying
Cases - TFIA-CC
Carrying Case for Model TFIA, TFIA-2 or TFIA-4 High Sampler
and filters (includes
shoulder strap).
TF-CCK
Carrying Case - for water proof storage and
carrying of Model TFIA Air Sampler, SH810
8”x10” Filter Holder, TR-1 Tripod, Filters and other
accessories.
TSP (Total
Suspended Particulate) Air Sampling Systems -
for U.S. EPA environmental ambient air sampling
PM10
Size Selective Inlet and Air Sampling Systems -
for U.S. EPA PM10 environmental air sampling. Staplex PM10
Size Selective Inlet is available separately as Part No.
PM10-SSI for conversion of existing TSP (Total Suspend
Particulate) High Volume Air Sampling Systems to PM10 Systems.
High
Volume Cascade Impactors, 4, 5 & 6 Stage models -
for particle size separation.
 
|